Loval logo

Small Packaged Units (Water-to-Air Heat Pumps) – 0.5 to 6 tons

The Tranquility® 30 Digital Series delivers the ultimate in efficiency, comfort, reliability and serviceability – intelligently driven by the iGate®, the industry’s first two-way communicating control, two-stage compressor, variable speed fan and industry-first vFlow® internal variable water flow components. The Tranquility 30 also delivers reliable operation, lower operating cost and compact installation.Available with multiple cabinet options (vertical upflow, vertical downflow and horizontal) the Tranquility 30 Digital offers a unit for most any installation. With an extended range refrigerant circuit, capable of ground loop (geothermal) applications as well as water loop (boiler-tower) applications, the Tranquility 30 Digital is among the most flexible in the industry. Standard features such as Copeland UltraTech™ two-stage scroll compressor, ECM variable fan motor, digital communicating controls, powder coated galvanized steel cabinet, stainless steel drain pan and foil-backed air handler insulation are just some of the features of the innovative Tranquility 30 Digital Series. The Tranquility 30 Digital Series also offers advanced options that allow for energy efficient, application flexibility. Available options include hot water generator, enhanced iGate digital communicating controls, coated air coils, extended range insulation, UltraQuiet package, vFlow internal variable water flow, and internal secondary circulator.

  • Sizes 026 (2 ton, 7.0 kW) through 072 (6 tons, 19.3 kW)
  • Advanced Controls – iGate communicating control provides advanced unit functionality and comprehensive configuration, monitoring and diagnostic capabilities through digital communication links with the variable-speed fan motor, variable-speed source pump (or modulating valve) and communicating thermostat or configuration/diagnostic tool.
  • Internal Variable Water Flow – Industry-first, built-in vFlow replaces a traditionally inefficient, external component of the geothermal system (water circulation) with an ultra-high efficient, variable speed, internal water flow system consisting of an internal variable speed circulator or an internal modulating motorized water valve.
  • EarthPure® (HFC-410A) refrigerant
  • Copeland UltraTech™ two-stage scroll compressors
  • ECM variable speed communicating fan motor with soft start
  • Exceeds ASHRAE 90.1 efficiencies
  • Part load operation significantly lowers annual operating costs
  • Galvanized steel construction with black mat polyester powder coat paint and silver accents
  • Stainless steel drain pan
  • Unique double isolation compressor mounting for quiet operation
  • TXV metering device
  • Extended range (20 to 120°F, -6.7 to 48.9°C) operation
  • Eight safeties standard
  • ClimaDry® II Modulating Reheat Option

Downloads (Literature)

  1. Easy access control box contains DXM2 (iGate) communicating control, a robust microprocessor based controller that is advanced and feature-laden for maximum application flexibility. (Optional DDC Controllers also available)
  2. Industry-first, built-in vFlow® replaces traditionally inefficient, external pumping components with an ultra-high efficient, variable speed, internal water flow system to intelligently vary the water flow to minimize pump energy consumption and improve system reliability.
  3. Easy to remove blower housing for quick service and ECM variable speed motor. Foil faced insulation in the blower section and fiberglass insulation in the compressor section.
  4. Copeland UltraTech™ two-stage compressor with dual compressor vibration isolation. Easy service access from multiple sides.

TE Series

1) DXM2

2) vFlow

3) Motor

4) Compressor

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TE 026-072

208-230/60/1

DXM2

ECM

None

With MOD Valve

96B0242N01

With ISP

96B0242N05

With Climadry®

96B0242N08

With Variable Pump

96B0242N12

LON

With MOD Valve

96B0242N02

With ISP

96B0242N06

With Climadry®

96B0242N20

With Variable Pump

96B0242N56

MPC

With MOD Valve

96B0242N03

With ISP

96B0242N07

With Climadry®

96B0242N21

With Variable Pump

96B0242N55

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TE 026-072

265/60/1

DXM2

ECM

None

With MOD Valve

96B0242N01

With ISP

96B0242N05

With Climadry®

96B0242N08

With Variable Pump

96B0242N09

LON

With MOD Valve

96B0242N02

With ISP

96B0242N06

With Climadry®

96B0242N20

With Variable Pump

96B0242N57

MPC

With MOD Valve

96B0242N03

With ISP

96B0242N07

With Climadry®

96B0242N21

With Variable Pump

96B0242N58

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TE 026-072

208-230/60/3

DXM2

ECM

None

With MOD Valve

96B0243N01

With ISP

96B0243N05

With Climadry®

96B0243N08

With Variable Pump

96B0243N09

LON

With MOD Valve

96B0243N02

With ISP

96B0243N06

With Climadry®

96B0243N12

With Variable Pump

96B0242N61

MPC

With MOD Valve

96B0243N03

With ISP

96B0243N07

With Climadry®

96B0243N11

With Variable Pump

96B0242N62

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TE 026-072

460/60/3

DXM2

ECM

None

With MOD Valve

96B0244N01

With ISP

96B0244N05

With Climadry®

96B0244N08

With Variable Pump

96B0244N09

LON

With MOD Valve

96B0244N02

With ISP

96B0244N06

With Climadry®

96B0244N11

With Variable Pump

96B0242N59

MPC

With MOD Valve

96B0244N03

With ISP

96B0244N07

With Climadry®

96B0244N10

With Variable Pump

96B0242N60

TIF for Print, JPG for Web, PNG for Presentations
TIFs and PNGs have transparent backgrounds, JPGs have white backgrounds

Tranquility® 30 Two-Stage
(TE) Series - Family

Tranquility® 30 Two-Stage
(TE) Series - Horizontal (no filter)

Tranquility® 30 Two-Stage
(TE) Series - Vertical

Tranquility® 30 Two-Stage
(TE) Series - Vertical Open

The Tranquility® High-Efficiency (TZ) Series offers high efficient 2-stage operation in a simple cabinet design.The Tranquility High-Efficiency Series also offers options that allow for application flexibility. Available options include hot water generator, enhanced iGate® controls, coated air coils, extended range insulation, UltraQuiet package, vFlow® internal variable water flow, motorized water valve, and automatic water flow valves.

  • Sizes 024 (2 ton, 7.0 kW) through 060 (5 tons, 17.6 kW)
  • Copeland UltraTech 2-stage scroll compressor
  • Exceeds ASHRAE 90.1 efficiencies
  • Galvanized steel construction
  • Corrosion resistant polymer drain pan (optional stainless steel drain pan)
  • Sound absorbing glass fiber insulation
  • Unique double isolation compressor mounting for quiet operation
  • Insulated divider & separate compressor/air handler compartments
  • Field convertible discharge air arrangement for horizontal units
  • Variable speed ECM fan motor
  • Internally trapped condensate drain line (vertical units only)
  • Eight safeties standard
  • Extended range (20 – 120°F, -6.7 – 48.9°C) capable
  • Advanced Controls — iGate communicating control provides advanced unit functionality & comprehensive configuration, monitoring & diagnostic capabilities through digital communication links with the variable-speed fan motor, variable-speed source pump (or modulating valve) & communicating thermostat or Configuration/Diagnostic tool.
  • Internal Variable Water Flow — Industry-first, Built-in vFlow replaces a traditionally inefficient, external component of the geothermal system (water circulation) with an ultra-high-efficient, variable speed, internal water flow system.

Downloads (Literature)

  1. Easy to remove blower housing for quick service and variable speed ECM fan motor. Easy service access from multiple sides.
  2. Dual compressor vibration isolation for quiet operation.
  3. Easy access control box contains advanced digital controls with Remote Service Sentinel. Optional DDC controllers are available. iGate® Advanced Control.
  4. Corrosion resistant polymer drain pan with condensate overflow protection.

TZ Series

1) DXM2

2) vFlow®

3) Motor

4) Compressor

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TZ 024-060

208-230/60/1

DXM2

ECM

None

None

96B0231N11

Mod Valve

96B0242N40

ISP

96B0242N45

LON

None

96B0231N12

Mod Valve

96B0242N41

ISP

96B0242N46

MPC

None

96B0231N13

Mod Valve

96B0242N42

ISP

96B0242N47

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TZ 024-060

265/60/1

DXM2

ECM

None

None

96B0231N11

Mod Valve

96B0242N40

ISP

96B0242N45

LON

None

96B0231N12

Mod Valve

96B0242N41

ISP

96B0242N46

MPC

None

96B0231N13

Mod Valve

96B0242N42

ISP

96B0242N47

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TZ 024-060

208-230/60/3

DXM2

ECM

None

None

96B0232N21

Mod Valve

96B0243N40

ISP

96B0243N45

LON

None

96B0232N22

Mod Valve

96B0243N41

ISP

96B0243N46

MPC

None

96B0232N23

Mod Valve

96B0243N42

ISP

96B0243N47

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TZ 024-060

460/60/3

DXM2

ECM

None

None

96B0232N31

Mod Valve

96B0244N40

ISP

96B0244N45

LON

None

96B0232N32

Mod Valve

96B0244N41

ISP

96B0244N46

MPC

None

96B0232N33

Mod Valve

96B0244N42

ISP

96B0244N47

TIF for Print, JPG for Web, PNG for Presentations
TIFs and PNGs have transparent backgrounds, JPGs have white backgrounds

Tranquility® 22 Digital Two-Stage
(TZ) Series

Tranquility® 22 Digital Two-Stage
(TZ) Series - Horizontal

Tranquility® 22 Digital Two-Stage
(TZ) Series - Vertical

The Tranquility® 22 Compact (TY) Series raises the bar for water-source heat pump efficiencies, features and application flexibility. Not only does the Tranquility 22 Compact Series exceed ASHRAE 90.1 efficiencies with 2-stage operation. It also uses EarthPure® (HFC-410A) zero ozone depletion refrigerant, making it an extremely environmentally-friendly option.

With one of the smallest cabinets in the industry, the Tranquility 22 Compact (TY) Series will easily fit into tight spaces. Designed to be backward compatible with thousands of older water-source heat pumps, the Tranquility 22 Compact (TY) Series heat pump is packed full of the innovation you have come to expect from the experts at ClimateMaster such as the iGate® advanced control making the TY Series easy to operate and install.

  • Sizes 024 (2 ton, 7.0 kW) – 060 (5 tons, 17.6 kW)
  • Copeland Ultra-Tech 2-stage scroll compressor
  • EarthPure® (HFC-410A) refrigerant
  • Exceeds ASHRAE 90.1 efficiencies
  • Galvanized steel construction
  • Corrosion resistant polymer drain pan (optional stainless steel drain pan)
  • Sound absorbing glass fiber insulation
  • Unique double isolation compressor mounting for quiet operation
  • Insulated divider & separate compressor/air handler compartments
  • TXV metering device
  • Field convertible discharge air arrangement for horizontal units
  • Variable speed ECM fan motor
  • Internally trapped condensate drain line (vertical units)
  • Advanced Controls — iGate communicating control provides advanced unit functionality & comprehensive configuration, monitoring & diagnostic capabilities through digital communication links with the variable-speed fan motor, & communicating thermostat or Configuration/Diagnostic tool

Downloads (Literature)

  1. Easy to remove blower housing for quick service & variable-speed ECM motor. Easy service access from multiple sides.
  2. Dual compressor vibration isolation for quiet operation.
  3. Easy access control box contains advanced digital controls with Remote Service Sentinel. Optional DDC controllers are available. iGate® advanced control.
  4. Corrosion resistant polymer drain pan with condensate overflow protection.

1) Motor

2) Compressor

3) Control Board

4) Condensate & Sensor

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Wiring Diagrams

TY 024-060

208-230/60/1

DXM2

ECM

None

96B0231N11

LON

96B0231N12

MPC

96B0231N13

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Wiring Diagrams

TY 024-060

265/60/1

DXM2

ECM

None

96B0231N11

LON

96B0231N12

MPC

96B0231N13

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Wiring Diagrams

TY 024-060

208-230/60/3

DXM2

ECM

None

96B0232N21

LON

96B0232N22

MPC

96B0232N23

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Wiring Diagrams

TY 024-060

460/60/3

DXM2

ECM

None

96B0232N31

LON

96B0232N32

MPC

96B0232N33

TIF for Print, JPG for Web, PNG for Presentations
TIFs and PNGs have transparent backgrounds, JPGs have white backgrounds

Tranquility® 22 Digital Compact
Two-Stage (TY) Series

Tranquility® 22 Digital Compact
Two-Stage (TY) Series - Horizontal

Tranquility® 22 Digital Compact
Two-Stage (TY) Series - Vertical

The Tranquility 20 Single-Stage (TS) Series builds on ClimateMaster’s commitment to utilizing the most advanced technology and design to create one of the most efficient single-stage water-source heat pump available today. The Tranquility 20 Single-Stage Series combines EarthPure® (HFC-410A) refrigerant with the Scroll compressor (rotary in 012 and smaller) and either an ECM variable speed or PSC multi-speed fan motor to create unmatched performance and flexibility.

  • Sizes 006 (½ ton, 1.8 kW) – 070 (6 ton, 21.1 kW2)
  • Environmentally-friendly EarthPure® (HFC-410A) refrigerant
  • Unsurpassed efficiencies (far exceeds ASHRAE 90.1)
  • Copeland Scroll compressor (size 018 & above)
  • Multi-speed PSC fan motor (optional variable speed ECM motor on size 018 & above
  • Galvanized steel construction & powder coat paint on all units
  • Unique double isolation compressor mounting for quiet operation
  • Discharge muffler standard (except rotary compressors) for superior sound attenuation
  • Microprocessor controls standard (optional DXM and/or DDC controls)
  • Field convertible discharge air arrangement for horizontal units
  • Bi-directional, balanced port expansion valve refrigerant metering device standard
  • Standard range or extended range operation
  • Water connections securely mounted flush to the cabinet corner post (no backup wrench required)
  • 8 safeties standard
  • ClimaDry® II Modulating Reheat Option

Downloads (Literature)

  1. Easy access control box contains advanced digital controls with Remote Service Sentinel. Optional enhanced controls (DXM) & DDC controllers.
  2. Standard stainless steel insulated drain pan with condensate overflow protection.
  3. Easy to remove blower housing for quick service & optional variable-speed ECMmotor. Foil faced insulation in the blower section & fiberglass insulation in the compressor section.
  4. Dual compressor vibration isolation for quiet operation. Easy service from multiple sides.

TS Series

1) Control Board

2) Condensate & Sensor

3) Motor

4) Compressor

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

208-230/60/1

CXM

PSC

None

None

96B0308N01

LON

None

96B0308N02

MPC

None

96B0308N03

ECM

None

None

96B0308N06

LON

None

96B0308N07

MPC

None

96B0308N08

 


Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

208-230/60/1

DXM2

PSC

None

None

96B0309N01

w/Climadry®

96B0309N11

LON

None

96B0309N02

w/Climadry®

96B0309N12

MPC

None

96B0309N03

w/Climadry®

96B0309N13

ECM

None

None

96B0309N06

w/Climadry®

96B0309N15

LON

None

96B0309N07

w/Climadry®

96B0309N16

MPC

None

96B0309N08

w/Climadry®

96B0309N17


 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

265/60/1

CXM

PSC

None

None

96B0308N01

LON

None

96B0308N02

MPC

None

96B0308N03

ECM

None

None

96B0308N06

LON

None

96B0308N07

MPC

None

96B0308N08
 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

265/60/1

DXM2

PSC

None

None

96B0309N01

w/Climadry®

96B0309N11

LON

None

96B0309N02

w/Climadry®

96B0309N12

MPC

None

96B0309N03

w/Climadry®

96B0309N13

ECM

None

None

96B0309N06

w/Climadry®

96B0309N15

LON

None

96B0309N07

w/Climadry®

96B0309N16

MPC

None

96B0309N08

w/Climadry®

96B0309N17

 

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

208-230/60/3

CXM

PSC

None

None

96B0310N01

LOM

None

96B0310N02

MPC

None

96B0310N03

ECM

None

None

96B0310N06

LON

None

96B0310N07

MPC

None

96B0310N08
 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

208-230/60/3

DXM2

PSC

None

None

96B0311N01

w/Climadry®

96B0311N11

LON

None

96B0311N02

w/Climadry®

96B0311N12

MPC

None

96B0311N03

w/Climadry®

96B0311N13

ECM

None

None

96B0311N06

w/Climadry®

96B0311N15

LON

None

96B0311N07

w/Climadry®

96B0311N16

MPC

None

96B0311N08

w/Climadry®

96B0311N17

 

 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

460/60/3

CXM

PSC

None

None

96B0312N01

LON

None

96B0312N02

MPC

None

96B0312N03

ECM

None

None

96B0312N06

LON

None

96B0312N07

MPC

None

96B0312N08
 

Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Options

Wiring Diagrams

TS 006-070

460/60/3

DXM2

PSC

None

None

96B0313N01

w/Climadry®

96B0313N11

LON

None

96B0313N02

w/Climadry®

96B0313N12

MPC

None

96B0313N03

w/Climadry®

96B0313N13

ECM

None

None

96B0313N06

w/Climadry®

96B0313N15

LON

None

96B0313N07

w/Climadry®

96B0313N16

MPC

None

96B0313N08

w/Climadry®

96B0313N17

TIF for Print, JPG for Web, PNG for Presentations
TIFs and PNGs have transparent backgrounds, JPGs have white backgrounds

Tranquility® 20 Single-Stage
(TS) Series - Family

Tranquility® 20 Single-Stage
(TS) Series - Family Open

Tranquility® 20 Single-Stage
(TS) Series - Vertical

Tranquility® 20 Single-Stage
(TS) Series - Horizontal

Tranquility® 20 Single-Stage
(TS) Series - Horizontal Open

The Tranquility® 16 (TR) Versatile Series raises the bar for water-source heat pump features and application flexibility. Not only does the Tranquility TR exceed ASHRAE 90.1 efficiencies, but it also uses EarthPure® HFC-410A zero ozone depletion refrigerant, making it an extremely environmentally-friendly option. Tranquility TR is eligible for LEED (Leadership in Energy and Environmental Design) points because of the “green” technology design. The Tranquility TR stands out as having the most comprehensive set of product options contained in a compact footprint making it the value leader in water source heat pump products.

  • Sizes 006 (1/2 ton, 1.8 kW) – 060 (5 tons, 17.6 kW)
  • Exceeds ASHRAE 90.1 efficiencies
  • Galvanized steel construction
  • Corrosion resistant polymer drain pan (optional stainless steel drain pan)
  • Sound absorbing glass fiber insulation
  • Unique double isolation compressor mounting for quiet operation
  • Insulated divider and separate compressor/air handler compartments
  • Copeland scroll compressors (Size 024 and above)
  • Microprocessor controls standard (optional DDC controls)
  • Optional DXM2 control simplifies installation and commissioning
  • Field convertible discharge air arrangement for horizontal units
  • PSC 3-speed fan motor
  • Optional CT ECM or CV ECM available on all sizes
  • Internally trapped condensate drain line (vertical units only)
  • Eight safeties standard
  • Extended range (20 – 120°F, -6.7 – 48.9°C) capable

FEATURES

  • Sizes 006 (1/2 ton, 1.76 kW) through 060 (5 tons, 17.6 kW)
  • Environmentally-friendly EarthPure® (HFC-410A)
    zero ozone depletion refrigerant
  • Exceeds ASHRAE 90.1 efficiencies
  • Coaxial heat exchanger
  • Galvanized steel construction
  • Sound absorbing glass fiber insulation
  • Unique double isolation compressor mounting for quiet operation
  • Insulated divider and separate compressor/air handler compartments
  • TXV metering device
  • Microprocessor controls with on board fuse and emergency shutdown
  • Field convertible discharge air arrangement for horizontal units
  • PSC three-speed fan motor (2 speed for 575 volt)
  • Unit Performance Sentinel performance monitoring system
  • Eight Safeties Standard
  • Non-corrosive polymer drain pan
  • iGate® 2 Communicating Controls Powered by CXM2
    • Multiple communication pathways,
      • Cloud-based connectivity via iGate 2 Wi-Fi communicating color touch screen thermostat for remote monitoring, access, and diagnosis. Including the new functionality for contractors/building engineers to monitor and make mass changes on multi-unit systems
      • Connect directly to the system with use of a handheld service tool
    • Provides real-time unit operating conditions
    • Reduces start-up, commissioning, and service time by removing the need for hard tooling to take temperature measurements
    • Captures operating conditions in the event of a safety shutdown 

OPTIONS

  • iGate® 2 Communicating Controls Powered by DXM2.5
    • Includes all of the features listed above for CXM2 controls including cloud-based connectivity via iGate 2 WiFi communicating color touch screen thermostat for remote monitoring, access, and diagnosis
    • Provides direct control over intelligent Constant Volume (CV) ECM fan motor
    • Controls ClimaDry® II hydronic modulating reheat
    • Allows operation of domestic Hot Water Generator
      (HWG)
  • Hybrid hydronic heating
  • High efficient ECM fan motors
    • Intelligent Constant Volume (CV) ECM motors for ultimate airflow control
    • Entry level Constant Torque (CT) ECM motors that provide efficiency at a value
  • High Static PCS fan motors
  • BACnet, Modbus and Johnson N2 compatibility options for DDC controls
  • Corrosive resistant cupro-nickel water heat exchanger
  • UltraQuiet sound attenuation package
  • Tin-plated air coils for added protection from formicary corrosion
  • Hot water generator for domestic hot water generation
  • Internally mounted water pump for single pipe systems
  • Auto flow regulators that limit water flow to the unit preventing system over pumping
  • Two-way motorized water valves that prevent water flow through the unit when it is not in operation increasing system pumping efficiency
  • ClimaDry® II modulating reheat
  • Easy to clean rust prohibitive stainless steel drain pans
  • Unit integrated power disconnect
  • Extended range insulation for geothermal applications

ACCESSORIES

  • Wi-Fi communicating color touch screen thermostat
  • Wide variety of thermostat options to meet your application needs
  • Various length braided hose kits with optional water valves, PT plugs, blowdown valve, flow limiting, and strainer options
  • Externally mounted manual and motorized water valves
  • 1” Merv 8 filter
  • 2” Merv 8 or 13 filters
  • Architecturally pleasing wall sensors for connection to DDC (MPC) controls
  • Electric emergency duct heaters
  1. Dual compressor vibration isolation for quiet operation.
  2. Easy to remove blower housing for quick service & PSC 3-speed motor. Easy service access from multiple sides.
  3. Easy access control box contains advanced communicating controls that can be coupled with a communicating thermostat remote control and diagnostics. Optional enhanced DXM2.5 controls offer maximized airflow control when paired with Constant Volume (CV) ECM fan motor and MPC controllers offer connection to building management systems.
  4. Corrosion resistant polymer drain pan with condensate overflow protection.

TR Series

1) Compressor

2) Blower

3) Control Board

4) Condensate & Sensor

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 006-012

Wiring Diagram

TR 015-060

208v/1

CXM2

PSC

None

96B0514N11

CT ECM

None

96B0514N12

Hybrid

96B0516N12

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 006-012

Wiring Diagram

TR 015-060

208v/1

DXM2.5

PSC

None

96B0521N11

Reheat

N/A

96B0524N11

CT ECM

None

96B0527N11

Hybrid

96B0532N11

Reheat

N/A

96B0528N11

CV ECM

None

96B0523N01

96B0523N11

Hybrid

96B0530N01

96B0530N11

Reheat

N/A

96B0525N11

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 006-012

Wiring Diagram

TR 015-060

265v/1

CXM2

PSC

None

96B0514N11

CT ECM

None

96B0514N12

Hybrid

96B0516N12

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 006-012

Wiring Diagram

TR 015-060

265v/1

DXM2.5

PSC

None

96B0521N11

Reheat

N/A

96B0524N11

CT ECM

None

96B0527N11

Hybrid

96B0532N11

Reheat

N/A

96B0528N11

CV ECM

None

96B0523N01

96B0523N11

Hybrid

96B0530N01

96B0530N11

Reheat

N/A

96B0525N11

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 024-060

208v/3

CXM2

PSC

None

96B0514N21

CT ECM

None

96B0514N22

Hybrid

96B0516N22

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 024-060

208v/3

DXM2.5

PSC

None

96B0521N21

Reheat

96B0524N21

CT ECM

None

96B0527N21

Hybrid

96B0532N21

Reheat

96B0528N21

CV ECM

None

96B0523N21

Hybrid

96B0530N21

Reheat

96B0525N21

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 024-060

460v/3

CXM2

PSC

None

96B0514N31

CT ECM

None

96B0514N32

Hybrid

96B0516N32

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 024-060

460v/3

DXM2.5

PSC

None

96B0521N31

Reheat

96B0524N31

CT ECM

None

96B0527N31

Hybrid

96B0532N31

Reheat

96B0528N31

CV ECM

None

96B0523N31

Hybrid

96B0530N31

Reheat

96B0525N31

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 042-060

575v/3

CXM2

PSC

None

96B0514N31

CT ECM

None

N/A

Hybrid

N/A

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

Electical

V-Hz-Ph

Unit Controller

Fan Motor

Hydronic Coil

Wiring Diagram

TR 024-060

575v/3

DXM2.5

PSC

None

96B0521N31

Reheat

N/A

CT ECM

None

N/A

Hybrid

N/A

Reheat

N/A

CV ECM

None

N/A

Hybrid

N/A

Reheat

N/A

Auxiliary WD for MPC Controls

96B0147N14

Control Box Layout

96B0500N00

The award winning Tranquility® 16 (TC) Compact Series raises the bar for water-source heat pump efficiencies, features and application flexibility. Not only does the Tranquility TC exceed ASHRAE 90.1 efficiencies, but it also uses EarthPure® HFC-410A zero ozone depletion refrigerant, making it an extremely environmentally-friendly option. Tranquility TC is eligible for LEED® (Leadership in Energy and Environmental Design) points because of the “green” technology design. With one of the smallest cabinets in the industry, the Tranquility TC will easily fit into tight spaces. Designed to be backward compatible with thousands of older water-source heat pumps, the Tranquility 16 (TC) Compact Series heat pump is packed full of the innovation you have come to expect from the experts at ClimateMaster.

FEATURES

  • Sizes 006 (1/2 ton, 1.76 kW) through 060 (5 tons, 17.6 kW)
  • Environmentally-friendly EarthPure® (HFC-410A)
    zero ozone depletion refrigerant
  • Exceeds ASHRAE 90.1 efficiencies
  • Coaxial heat exchanger
  • Galvanized steel construction
  • Sound absorbing glass fiber insulation
  • Unique double isolation compressor mounting for quiet operation
  • Insulated divider and separate compressor/air handler compartments
  • TXV metering device
  • Microprocessor controls with on board fuse and emergency shutdown
  • Field convertible discharge air arrangement for horizontal units
  • PSC three-speed fan motor (2 speed for 575 volt)
  • Unit Performance Sentinel performance monitoring system
  • Eight Safeties Standard
  • Non-corrosive polymer drain pan
  • iGate® 2 Communicating Controls Powered by CXM2
    • Multiple communication pathways,
      • Cloud-based connectivity via iGate 2 Wi-Fi communicating color touch screen thermostat for remote monitoring, access, and diagnosis. Including the new functionality for contractors/building engineers to monitor and make mass changes on multi-unit systems
      • Connect directly to the system with use of a handheld service tool
    • Provides real-time unit operating conditions
    • Reduces start-up, commissioning, and service time by removing the need for hard tooling to take temperature measurements
    • Captures operating conditions in the event of a safety shutdown 

OPTIONS

  • iGate® 2 Communicating Controls Powered by DXM2.5
    • Includes all of the features listed above for CXM2 controls including cloud-based connectivity via iGate 2 WiFi communicating color touch screen thermostat for remote monitoring, access, and diagnosis
    • Provides direct control over intelligent Constant Volume (CV) ECM fan motor
  • High Static PSC Fan Motors
  • BACnet, Modbus and Johnson N2 compatibility options for DDC controls
  • Corrosive resistant cupro-nickel water heat exchanger
  • UltraQuiet sound attenuation package
  • High efficient ECM fan motors
    • Intelligent Constant Volume (CV) ECM motors for ultimate airflow control
    • Entry level Constant Torque (CT) ECM motors that provide efficiency at a value
  • Waterside Economizer (WSE)
  • Easy to clean rust prohibitive stainless steel drain pans
  • Electrical service disconnect
  • Extended range insulation for geothermal applications
  • Tin-plated air coils for added protection from formicary corrosion

ACCESSORIES

  • Wi-Fi communicating color touch screen thermostat
  • Wide variety of thermostat options to meet your application needs
  • Various length braided hose kits with optional water valves, PT plugs, blowdown valve, flow limiting, and strainer options
  • Externally mounted manual and motorized water valves
  • 1” Merv 8 filter
  • 2” Merv 8 or 13 filters
  • Architecturally pleasing wall sensors for connection to DDC (MPC) controls
  • Electric emergency duct heaters
  1. Dual compressor vibration isolation for quiet operation.
  2. Easy to remove blower housing for quick service of 3-speed PSC, 5-speed CT ECM or variable speed CV ECM fan motor. Easy service from multiple sides.
  3. Easy access control box contains advanced communicating controls that can be coupled with a communicating thermostat remote control and diagnostics. Optional enhanced DXM2.5 controls offer maximized airflow control when paired with Constant Volume (CV) ECM fan motor and
    MPC controllers offer connection to building management systems.
  4. Corrosion resistant polymer drain pan with condensate overflow protection.
  5. Optional water side economizer to maximize energy efficiency and meet code requirements

TC Series

1) Compressor

2) Blower

3) Control Board

4) Condensate & Sensor

5) Water Side Economizer

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 006-060

208v/1 - 265v/1

CXM2

PSC

None

96B0514N11

WSE

96B0515N11

CT ECM

None

96B0514N12

WSE

96B0515N12

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 006-012

Wiring Diagram

TC 015-060

208v/1 - 265v/1

DXM2.5

PSC

None

96B0521N11

WSE

96B0476N11

CT ECM

None

96B0527N11

WSE

96B0478N11

CV ECM

None

96B0523N01

96B0523N11

WSE

96B0477N01

96B0477N21

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 024-060

208v3

CXM2

PSC

None

96B0514N21

WSE

96B0515N21

CT ECM

None

96B0514N22

WSE

96B0515N22

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 024-060

208v3

DXM2.5

PSC

None

96B0521N21

WSE

96B0476N21

CT ECM

None

96B0527N21

WSE

96B0478N21

CV ECM

None

96B0523N21

WSE

96B0477N21

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 024-060

460v/3

CXM2

PSC

None

96B0514N31

WSE

96B0515N31

CT ECM

None

96B0514N32

WSE

96B0515N32

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 024-060

460v/3

DXM2.5

PSC

None

96B0521N31

WSE

96B0476N31

CT ECM

None

96B0527N31

WSE

96B0478N31

CV ECM

None

96B0523N31

WSE

96B0477N31

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 041-060

575v/3

CXM2

PSC

None

96B0514N31

WSE

96B0515N31

CT ECM

None

N/A

WSE

N/A

Auxiliary WD for MPC Controls

96B0147N14

Electrical

V-Hz-Ph

Unit Controller

Fan Motor

Water Side Economizer

Wiring Diagram

TC 024-060

575v/3

DXM2

PSC

None

96B0521N31

WSE

96B0476N31

CT ECM

None

N/A

WSE

N/A

CV ECM

None

N/A

WSE

N/A

Auxiliary WD for MPC Controllers

6B0147N14


The Tranquility® TRL Series introduces the next generation in technology of commercial water source heat pumps. Its unmatched low-profile height allows it to be installed in ceiling spaces as low as 12” in height. This space saving solution gives architects greater freedom when designing buildings. When compared to other horizontal water source heat pumps on the market, the TRL series allows building owners the ability to reduce floor to floor slab height saving money in construction materials.

Tranquility TRL products offer integrated water control options that save system watts by preventing over pumping both when the unit is in operation and when its not. ECM fan motors maximize the systems airflow movement efficiency. Advanced communicating controls offer reduced startup and commissioning time by providing an easy to read gateway into the system operating conditions. The low-profile product series design is paired with industry exclusive serviceability features along with many options for increased application flexibility and system efficiency.

  • Available in sizes 006 (1/2 ton) through 015 (1.25 ton)
  • All sizes have a low 9" height cabinet design!
  • ECM Constant Torque fan motor
  • Braze-plate heat exchanger
  • iGate® Advanced Communicating Controls for reduced start up, commisioning and service time
  • Nine standard safeties including water flow confirmation switch
  • Integrally designed sound reducing attenuator box
  • Unique double isolation compressor mounting for quiet operation
  • Robust service tool connection located on the unit outside corner post
  • Stainless steel drain pain
  • 20 mesh water strainer

Downloads (Literature)


  1. 9" height
  2. Bottom access
  3. Sound attenuation box
  4. Service tool connection
  5. Brazed plate heat exchanger
  6. Swiveling controls
  7. Integrated water options (MWV, AFR)
  8. Flow switch safety protection

1) 9" height

2) Bottom access

3) Sound attenuation box

4) Service tool connection

5) Brazed plate heat exchanger

6) Swiveling controls

7) Integrated water options
(MWV, AFR)

8) Flow switch safety protection


Electrical

V-Hz-Ph

Control

Fan Motor

DDC

Wiring Diagram

TRL 006-012

208-230/60/1

CXM2

ECM-CT

None

96B1001N01

MPC

96B1001N02

TIF for Print, JPG for Web, PNG for Presentations
TIFs and PNGs have transparent backgrounds, JPGs have white backgrounds

Tranquility® Low Profile
(TRL) Series - Bottom Angle

Tranquility® Low Profile
(TRL) Series - Front Left Top

Tranquility® Low Profile
(TRL) Series - Blowers

ClimateMaster, Inc.

7300 S.W. 44th Street

Oklahoma City, OK 73179

(405)745-6000

Learn more about other Climate Control Group companies

CCG | ClimaCool | ClimateCraft | IEC

© ClimateMaster, Inc. All rights reserved 2023